Single-Core PVC Insulated Non-Sheated Cables
Conductor: copper
Insulation: PVC
Outer sheath: Nil
Colour: Brown, Blue, Red, Black, Yellow/Green or as per customer’s request
Voltage rating (Uo/U): 450/750V
Operating temperature: 70°C
SPEC. : SS358(IEC 60227-3) & BS EN50525-2-31
Industry Uses: Public & Private Residential, Commercial & Data Centre, Institutions, Transportation, Oil & Gas, Power Plant / Substation
Refer Table P1 & P2
Download PDF
Technical Data Part 1
Technical Data Part 2
Single-Core PVC Insulated PVC Sheathed Cables
Conductor: copper
Insulation: PVC Type A
Colour: Brown, Blue, Red or Black
Outer sheath: PVC Type ST1
Colour: Grey or Black
Voltage rating (Uo/U): 600/1000V
Operating temperature: 70°C
SPEC. : IEC 60502-1
Industry Uses: Public & Private Residential, Commercial & Data Centre, Institutions, Transportation, Oil & Gas, Power Plant / Substation
Download PDF
Technical Data Part 1
Technical Data Part 2
Single-Core PVC Insulated And PVC Sheathed Armoured Cables
Conductor: Plain annealed copper conductor
Insulation: PVC Type A
Armour: Aluminium steel wire
Bedding & Outer sheath: PVC ST1
Insulation colour: Brown or Blue
Outer sheath colour: Black
Voltage rating (Uo/U): 600/1000V
Operating temperature: 70°C
SPEC. : IEC 60502-1
Industry Uses: Public & Private Residential, Commercial & Data Centre, Institutions, Transportation, Oil & Gas, Power Plant / Substation
Refer Table A1
Download PDF
Technical Data Part 1
Technical Data Part 2
Multi-Core PVC Insulated PVC Sheathed Cables
Conductor: copper
Insulation: PVC Type A
Colour:
2C: (Brown, Blue) or (Red, Black)
3C: (Brown, Black,Grey) or (Red, Yellow,Blue)
4C: (Brown, Black,Grey,Blue) or (Red, Yellow,Blue,Black)
Outer sheath: PVC Type ST1
Colour: Black
Voltage rating (Uo/U): 600/1000V
Operating temperature: 70°C
SPEC. : IEC 60502-1
Industry Uses: Public & Private Residential, Commercial & Data Centre, Institutions, Transportation, Oil & Gas, Power Plant / Substation
Download PDF
Technical Data Part 1
Technical Data Part 2
Two-Core PVC Insulated And PVC Sheathed Armoured Cables
Conductor: Plain annealed copper conductor
Insulation: PVC Type A
Armour: Galvanized steel wire
Bedding & Outer sheath: PVC ST1
Insulation colour: (Brown,Blue) or (Red, Black)
Outer sheath colour: Black
Voltage rating (Uo/U): 600/1000V
Operating temperature: 70°C
SPEC. : IEC 60502-1
Industry Uses: Public & Private Residential, Commercial & Data Centre, Institutions, Transportation, Oil & Gas, Power Plant / Substation
Refer Table A2
Download PDF
Technical Data Part 1
Technical Data Part 2
Three-Core PVC Insulated And PVC Sheathed Armoured Cables
Conductor: Plain annealed copper conductor
Insulation: PVC Type A
Armour: Galvanized steel wire
Bedding & Outer sheath: PVC ST1
Insulation colour: (Brown,Black, Grey) or (Red, Yellow, Blue)
Outer sheath colour: Black
Voltage rating (Uo/U): 600/1000V
Operating temperature: 70°C
SPEC. : IEC 60502-1
Industry Uses: Public & Private Residential, Commercial & Data Centre, Institutions, Transportation, Oil & Gas, Power Plant / Substation
Refer Table A3
Download PDF
Technical Data Part 1
Technical Data Part 2
Four-Core PVC Insulated And PVC Sheathed Armoured Cables
Conductor: Plain annealed copper conductor
Insulation: PVC Type A
Armour: Galvanized steel wire
Bedding & Outer sheath: PVC ST1
Insulation colour: (Brown,Black, Grey, Blue) or (Red, Yellow, Blue, Black)
Outer sheath colour: Black
Voltage rating (Uo/U): 600/1000V
Operating temperature: 70°C
SPEC. : IEC 60502-1
Industry Uses: Public & Private Residential, Commercial & Data Centre, Institutions, Transportation, Oil & Gas, Power Plant / Substation
Refer Table A4
Download PDF
Technical Data Part 1
Technical Data Part 2
Single-Core XLPE Insulated PVC Sheathed, Non-Armoured Or Armoured Cables
Conductor: Plain annealed copper conductor
Insulation: XLPE
Bedding & Outer sheath: PVC ST2
Insulation colour: natural
Outer sheath colour: Black
Voltage rating (Uo/U): 600/1000V
Operating temperature: 90°C
SPEC. : IEC 60502-1
Industry Uses: Commercial & Data Centre, Institutions, Transportation, Oil & Gas, Power Plant / Substation
Refer Table XL1
Download PDF
Technical Data Part 1
Technical Data Part 2
Two-Core XLPE Insulated,Non-Armoured Or Armoured Cables
Conductor: Plain annealed copper conductor
Insulation: XLPE
Armour: Galvanized steel wire
Bedding & Outer sheath: PVC ST2
Insulation colour: (Brown,Blue) OR (Red, Black)
Outer sheath colour: Black
Voltage rating (Uo/U): 600/1000V
Operating temperature: 90°C
SPEC. : IEC 60502-1
Industry Uses: Commercial & Data Centre, Institutions, Transportation, Oil & Gas, Power Plant / Substation
Refer Table XL2
Download PDF
Technical Data Part 1
Technical Data Part 2
Three-Core XLPE Insulated XLPE Insulated PVC Sheathed, Non-Armoured Or Armoured Cables
Conductor: Plain annealed copper conductor
Insulation: XLPE
Armour: Galvanized steel wire
Bedding & Outer sheath: PVC ST2
Insulation colour: (Brown,Blue, Green/Yellow) or (Brown,Black, Grey) or (Red, Yellow, Blue)
Outer sheath colour: Black
Voltage rating (Uo/U): 600/1000V
Operating temperature: 90°C
SPEC. : IEC 60502-1
Industry Uses: Commercial & Data Centre, Institutions, Transportation, Oil & Gas, Power Plant / Substation
Refer Table XL3
Download PDF
Technical Data Part 1
Technical Data Part 2
Four-Core XLPE Insulated PVC Sheathed,Non-Armoured Or Armoured Cables
Conductor: Plain annealed copper conductor
Insulation: XLPE
Armour: Galvanized steel wire
Bedding & Outer sheath: PVC ST2
Insulation colour: (Brown,Black, Grey, Blue) or (Red, Yellow, Blue, Black)
Outer sheath colour: Black
Voltage rating (Uo/U): 600/1000V
Operating temperature: 90°C
SPEC. : IEC 60502-1
Industry Uses: Commercial & Data Centre, Institutions, Transportation, Oil & Gas, Power Plant / Substation
Refer Table XL4
Download PDF
Technical Data Part 1
Technical Data Part 2
Four-Core With Reduced Neutral XLPE Insulated PVC Sheathed,Non-Armoured Or Armoured Cables
Conductor: Plain annealed copper conductor
Insulation: XLPE
Armour: Galvanized steel wire
Bedding & Outer sheath: PVC ST2
Insulation colour: (Brown,Black, Grey, Blue) or (Red, Yellow, Blue, Black)
Outer sheath colour: Black
Voltage rating (Uo/U): 600/1000V
Operating temperature: 90°C
SPEC. : IEC 60502-1
Industry Uses: Commercial & Data Centre, Institutions, Transportation, Oil & Gas, Power Plant / Substation
Refer Table XL5
Download PDF
Technical Data Part 1
Technical Data Part 2
Single-Core Low Smoke Halogen Free Insulated Non-Sheathed Flame Retardant Cables
Conductor: Plain annealed copper conductor
Insulation: LSHF
Outer sheath: Nil
Insulation colour: Brown, Blue, Red, Black, Yellow / Green or as per customer’s request
Voltage rating (Uo/U): 450/750V or 600/1000V
Operating temperature: 90°C
SPEC. : REFER BS EN 50525-3-31, IEC 60332-3, IEC 60754 & IEC61034
Industry Uses: Commercial & Data Centre, Institutions, Transportation, Oil & Gas, Power Plant / Substation
Refer Table XL6
Download PDF
Technical Data Part 1
Technical Data Part 2
Single-Core XLPE Insulated Low Smoke Halogen Free Sheathed,Non Armoured Or Armoured Flame Retardant Cables
Conductor: Plain annealed copper conductor
Insulation: XLPE
Armour: Aluminium wire
Bedding & Outer sheath: LSHF
Insulation colour: natural
Outer sheath colour: Black
Voltage rating (Uo/U): 600/1000V
Operating temperature: 90°C
SPEC. : IEC 60502-1
Industry Uses: Commercial & Data Centre, Institutions, Transportation, Oil & Gas, Power Plant / Substation
Refer Table XL7
Download PDF
Technical Data Part 1
Technical Data Part 2
Multi-Core XLPE Insulated Low Smoke Halogen Free Sheathed,Non-Armoured Or Armoured Flame Retardant Cables
Conductor: Plain annealed copper conductor
Insulation: XLPE
Armour: Galvanized steel wire
Bedding & Outer sheath: LSHF
Insulation colour: (Brown, Black, Grey, Blue) or (Red, Yellow, Blue, Black)
Outer sheath colour: Black
Voltage rating (Uo/U): 600/1000V
Operating temperature: 90°C
SPEC. : IEC 60502-1 or BS 6724
Industry Uses: Commercial & Data Centre, Institutions, Transportation, Oil & Gas, Power Plant / Substation
Refer Table XL9
Download PDF
Technical Data Part 1
Technical Data Part 2
Single-Core EVA Insulated Non-Sheathed Fire-Resistant & Flame-Retardant Cable
Conductor: Plain annealed copper conductor
Fire barrier: Glass Mica
Insulation: EVA
Outer sheath: Nil
Insulation colour: Orange
Voltage rating (Uo/U): 470/750V or 600/1000V
Operating temperature: 90°C (up to 110°C)
SPEC. : REFER BS7211, BS EN 50525-3-41, BS6387, SS299, IEC60332-3, IEC 60754 & IEC61034
Industry Uses: Public & Private Residential, Commercial & Data Centre, Institutions, Transportation, Oil & Gas, Power Plant / Substation
Refer: Table FR2
Download PDF
Technical Data Part 1
Technical Data Part 2