Showing 1–16 of 27 results

Single-Core PVC Insulated Non-Sheathed Cables

Single-Core PVC Insulated Non-Sheated Cables

Conductor: copper
Insulation: PVC
Outer sheath: Nil
Colour: Brown, Blue, Red, Black, Yellow/Green or as per customer’s request
Voltage rating (Uo/U): 450/750V
Operating temperature: 70°C
SPEC. : SS358(IEC 60227-3) & BS EN50525-2-31

Industry Uses: Public & Private Residential, Commercial & Data Centre, Institutions, Transportation, Oil & Gas, Power Plant / Substation

Refer Table P1 & P2

Download PDF Technical Data Part 1

 

Technical Data Part 2

Single-Core PVC Insulated PVC Sheathed Cables

Single-Core PVC Insulated PVC Sheathed Cables

Conductor: copper
Insulation: PVC Type A
Colour: Brown, Blue, Red or Black
Outer sheath: PVC Type ST1
Colour: Grey or Black
Voltage rating (Uo/U): 600/1000V
Operating temperature: 70°C
SPEC. : IEC 60502-1

Industry Uses: Public & Private Residential, Commercial & Data Centre, Institutions, Transportation, Oil & Gas, Power Plant / Substation

Download PDF Technical Data Part 1

 

Technical Data Part 2

Single-Core PVC Insulated And PVC Sheathed Armoured Cables

Single-Core PVC Insulated And PVC Sheathed Armoured Cables

Conductor: Plain annealed copper conductor
Insulation: PVC Type A
Armour: Aluminium steel wire
Bedding & Outer sheath: PVC ST1
Insulation colour: Brown or Blue
Outer sheath colour: Black
Voltage rating (Uo/U): 600/1000V
Operating temperature: 70°C
SPEC. : IEC 60502-1

Industry Uses: Public & Private Residential, Commercial & Data Centre, Institutions, Transportation, Oil & Gas, Power Plant / Substation

Refer Table A1

Download PDF Technical Data Part 1

 

Technical Data Part 2

Multi-Core PVC Insulated PVC Sheathed Cables

Multi-Core PVC Insulated PVC Sheathed Cables

Conductor: copper
Insulation: PVC Type A
Colour:

  • 2C: (Brown, Blue) or (Red, Black)
  • 3C: (Brown, Black,Grey) or (Red, Yellow,Blue)
  • 4C: (Brown, Black,Grey,Blue) or (Red, Yellow,Blue,Black)

Outer sheath: PVC Type ST1
Colour: Black
Voltage rating (Uo/U): 600/1000V
Operating temperature: 70°C
SPEC. : IEC 60502-1

Industry Uses: Public & Private Residential, Commercial & Data Centre, Institutions, Transportation, Oil & Gas, Power Plant / Substation

 

Download PDF Technical Data Part 1

 

Technical Data Part 2

Two-Core PVC Insulated And PVC Sheathed Armoured Cables

Two-Core PVC Insulated And PVC Sheathed Armoured Cables

Conductor: Plain annealed copper conductor
Insulation: PVC Type A
Armour: Galvanized steel wire
Bedding & Outer sheath: PVC ST1
Insulation colour: (Brown,Blue) or (Red, Black)
Outer sheath colour: Black
Voltage rating (Uo/U): 600/1000V
Operating temperature: 70°C
SPEC. : IEC 60502-1

Industry Uses: Public & Private Residential, Commercial & Data Centre, Institutions, Transportation, Oil & Gas, Power Plant / Substation

Refer Table A2

Download PDF Technical Data Part 1

 

Technical Data Part 2

Three-Core PVC Insulated And PVC Sheathed Armoured Cables

Three-Core PVC Insulated And PVC Sheathed Armoured Cables

Conductor: Plain annealed copper conductor
Insulation: PVC Type A
Armour: Galvanized steel wire
Bedding & Outer sheath: PVC ST1
Insulation colour: (Brown,Black, Grey) or (Red, Yellow, Blue)
Outer sheath colour: Black
Voltage rating (Uo/U): 600/1000V
Operating temperature: 70°C
SPEC. : IEC 60502-1

Industry Uses: Public & Private Residential, Commercial & Data Centre, Institutions, Transportation, Oil & Gas, Power Plant / Substation

Refer Table A3

Download PDF Technical Data Part 1

 

Technical Data Part 2

Four-Core PVC Insulated And PVC Sheathed Armoured Cables

Four-Core PVC Insulated And PVC Sheathed Armoured Cables

Conductor: Plain annealed copper conductor
Insulation: PVC Type A
Armour: Galvanized steel wire
Bedding & Outer sheath: PVC ST1
Insulation colour: (Brown,Black, Grey, Blue) or (Red, Yellow, Blue, Black)
Outer sheath colour: Black
Voltage rating (Uo/U): 600/1000V
Operating temperature: 70°C
SPEC. : IEC 60502-1

Industry Uses: Public & Private Residential, Commercial & Data Centre, Institutions, Transportation, Oil & Gas, Power Plant / Substation

Refer Table A4

Download PDF Technical Data Part 1

 

Technical Data Part 2

Single-Core XLPE Insulated PVC Sheathed, Non-Armoured Or Armoured Cables

Single-Core XLPE Insulated PVC Sheathed, Non-Armoured Or Armoured Cables

Conductor: Plain annealed copper conductor
Insulation: XLPE
Bedding & Outer sheath: PVC ST2
Insulation colour: natural
Outer sheath colour: Black
Voltage rating (Uo/U): 600/1000V
Operating temperature: 90°C
SPEC. : IEC 60502-1

Industry Uses: Commercial & Data Centre, Institutions, Transportation, Oil & Gas, Power Plant / Substation

Refer Table XL1

Download PDF Technical Data Part 1

 

Technical Data Part 2

Two-Core XLPE Insulated,Non-Armoured Or Armoured Cables

Two-Core XLPE Insulated,Non-Armoured Or Armoured Cables

Conductor: Plain annealed copper conductor
Insulation: XLPE
Armour: Galvanized steel wire
Bedding & Outer sheath: PVC ST2
Insulation colour: (Brown,Blue) OR (Red, Black)
Outer sheath colour: Black
Voltage rating (Uo/U): 600/1000V
Operating temperature: 90°C
SPEC. : IEC 60502-1

Industry Uses: Commercial & Data Centre, Institutions, Transportation, Oil & Gas, Power Plant / Substation

Refer Table XL2

Download PDF
Technical Data Part 1

 

Technical Data Part 2

Three-Core XLPE Insulated XLPE Insulated PVC Sheathed, Non-Armoured Or Armoured Cables

Three-Core XLPE Insulated XLPE Insulated PVC Sheathed, Non-Armoured Or Armoured Cables

Conductor: Plain annealed copper conductor
Insulation: XLPE
Armour: Galvanized steel wire
Bedding & Outer sheath: PVC ST2
Insulation colour: (Brown,Blue, Green/Yellow) or (Brown,Black, Grey) or (Red, Yellow, Blue)
Outer sheath colour: Black
Voltage rating (Uo/U): 600/1000V
Operating temperature: 90°C
SPEC. : IEC 60502-1

Industry Uses: Commercial & Data Centre, Institutions, Transportation, Oil & Gas, Power Plant / Substation

Refer Table XL3

Download PDF Technical Data Part 1

 

Technical Data Part 2

Four-Core XLPE Insulated PVC Sheathed,Non-Armoured Or Armoured Cables

Four-Core XLPE Insulated PVC Sheathed,Non-Armoured Or Armoured Cables

Conductor: Plain annealed copper conductor
Insulation: XLPE
Armour: Galvanized steel wire
Bedding & Outer sheath: PVC ST2
Insulation colour: (Brown,Black, Grey, Blue) or (Red, Yellow, Blue, Black)
Outer sheath colour: Black
Voltage rating (Uo/U): 600/1000V
Operating temperature: 90°C
SPEC. : IEC 60502-1

Industry Uses: Commercial & Data Centre, Institutions, Transportation, Oil & Gas, Power Plant / Substation

Refer Table XL4

Download PDF Technical Data Part 1

 

Technical Data Part 2

Four-Core With Reduced Neutral XLPE Insulated PVC Sheathed,Non-Armoured Or Armoured Cables

Four-Core With Reduced Neutral XLPE Insulated PVC Sheathed,Non-Armoured Or Armoured Cables

Conductor: Plain annealed copper conductor
Insulation: XLPE
Armour: Galvanized steel wire
Bedding & Outer sheath: PVC ST2
Insulation colour: (Brown,Black, Grey, Blue) or (Red, Yellow, Blue, Black)
Outer sheath colour: Black
Voltage rating (Uo/U): 600/1000V
Operating temperature: 90°C
SPEC. : IEC 60502-1

Industry Uses: Commercial & Data Centre, Institutions, Transportation, Oil & Gas, Power Plant / Substation

Refer Table XL5

Download PDF Technical Data Part 1

 

Technical Data Part 2

Single-Core Low Smoke Halogen Free Insulated Non-Sheathed Flame Retardant Cables

Single-Core Low Smoke Halogen Free Insulated Non-Sheathed Flame Retardant Cables

Conductor: Plain annealed copper conductor
Insulation: LSHF
Outer sheath: Nil
Insulation colour: Brown, Blue, Red, Black, Yellow / Green or as per customer’s request
Voltage rating (Uo/U): 450/750V or 600/1000V
Operating temperature: 90°C
SPEC. : REFER BS EN 50525-3-31, IEC 60332-3, IEC 60754 & IEC61034

Industry Uses: Commercial & Data Centre, Institutions, Transportation, Oil & Gas, Power Plant / Substation

Refer Table XL6

Download PDF Technical Data Part 1

 

Technical Data Part 2

Single-Core XLPE Insulated Low Smoke Halogen Free Sheathed,Non Armoured Or Armoured Flame Retardant Cables

Single-Core XLPE Insulated Low Smoke Halogen Free Sheathed,Non Armoured Or Armoured Flame Retardant Cables

Conductor: Plain annealed copper conductor
Insulation: XLPE
Armour: Aluminium wire
Bedding & Outer sheath: LSHF
Insulation colour: natural
Outer sheath colour: Black
Voltage rating (Uo/U): 600/1000V
Operating temperature: 90°C
SPEC. : IEC 60502-1

Industry Uses: Commercial & Data Centre, Institutions, Transportation, Oil & Gas, Power Plant / Substation

Refer Table XL7

Download PDF Technical Data Part 1

 

Technical Data Part 2

Multi-Core XLPE Insulated Low Smoke Halogen Free Sheathed,Non-Armoured Or Armoured Flame Retardant Cables

Multi-Core XLPE Insulated Low Smoke Halogen Free Sheathed,Non-Armoured Or Armoured Flame Retardant Cables

Conductor: Plain annealed copper conductor
Insulation: XLPE
Armour: Galvanized steel wire
Bedding & Outer sheath: LSHF
Insulation colour: (Brown, Black, Grey, Blue) or (Red, Yellow, Blue, Black)
Outer sheath colour: Black
Voltage rating (Uo/U): 600/1000V
Operating temperature: 90°C
SPEC. : IEC 60502-1 or BS 6724

Industry Uses: Commercial & Data Centre, Institutions, Transportation, Oil & Gas, Power Plant / Substation

Refer Table XL9

Download PDF Technical Data Part 1

 

Technical Data Part 2

Single-Core EVA Insulated Non-Sheathed Fire-Resistant & Flame-Retardant Cable

Single-Core EVA Insulated Non-Sheathed Fire-Resistant & Flame-Retardant Cable

Conductor: Plain annealed copper conductor
Fire barrier: Glass Mica
Insulation: EVA
Outer sheath: Nil
Insulation colour: Orange
Voltage rating (Uo/U): 470/750V or 600/1000V
Operating temperature: 90°C (up to 110°C)
SPEC. : REFER BS7211, BS EN 50525-3-41, BS6387, SS299, IEC60332-3, IEC 60754 & IEC61034

Industry Uses: Public & Private Residential, Commercial & Data Centre, Institutions, Transportation, Oil & Gas, Power Plant / Substation

Refer: Table FR2

Download PDF Technical Data Part 1

 

Technical Data Part 2